When using F8 to copy a field from the previous line would copy all dimension fields.
This has been corrected
VSA reference: 8138645
P6) Name Field In Windows Login Table
Error
It was possible to see the name for the Windows Login created in the Windows Login Table.
This has been corrected
VSA reference: 8275508
P7) Printer Name Case Sensitive
Error
If the printer name was in the wrong case Navision would pick the default printer for print jobs. The printer name is now case insensitive.
This has been corrected
VSA reference: 8486918
P8) Look Up (F6) In A Field Filter (F7) Opens Wrong Form
Error
When applying a field filter with the F7 key and afterwards doing a look up with the F6 key would open the first table listed in the table relation conditions through its specific form instead of the specific table for the data you would do the lookup for.
This has been corrected
VSA reference: 8065628
P9) SQL ODBC Error Message - Operation Invalid At This Time
Error
An ODBC error message could occur when opening a database from the “Open Database” window and pressing cancel to database conversion. The “Open Database” dialogue will now close if database conversion is cancelled.
This has been corrected
P10) CTRL+A and CTRL+C Causes Crash In CITRIX Installations
Error
Doing a lookup on tables with many lines in a CITRIX installation marking all entries (CTRL+A) and copy them (CTRL+C) could cause a crash.
This has been corrected
P11) Opening A Sub Form Could Cause A Crash
Error
When opening a sub form it could lead to a crash if opened directly and not through the main form.
This has now been corrected
VSA reference: 7914251
P12) System Could Hang When Opening A New Database
Error
When opening a new database and trying to locate the database with the find as you type option Navision could hang.
This has been corrected
P13) Forms Did Not Open On Top Of Each Other
Error
When creating new forms and opening them would not make them open on top of each other.
This has been corrected
VSA reference: 8498130
P14) Link To Privacy Website Link In The About Box
Error
The link in the about box was pointing to a wrong an outdated website.
This has been corrected
P15) Wrong Paper Size When Printing
Error
Navision would return a wrong paper size when not recognizing the chosen paper format in the print process. Now Navision will always return the A4 size when the chosen paper size is not recognized by Navision.
This has been corrected
P16) Paste With CTRL+V Does Not Work
Error
When using CTRL+V to paste into fields in a input dialogue could cause a runtime error.
This has been corrected
P17) Wrong Language on Shortcut Buttons in Navigation Pane
Error
The navigation pane shortcuts did not change language when changing from one language to another in multi language versions.
This has been corrected
VSA reference: 8103105
P18) Fin.smt Is Not Accessible If You Are Not A Local Administrator
Error
It was not possible to access the fin.smt file for users not being local administrators when Navision was installed on the C:\ drive on a server.
This has been corrected
VSA reference: 8152246
P19) Not Possible To Use HotCopy
Error
It was not possible to use hotcopy to copy a database into two different folders on two different hard drives.
This has been corrected
VSA reference: 8210442
Issues
P20) System Texts Locked/Unlocked For Translation
Issue
String identifiers were set not to be translated and others were optional.
This has been corrected
Fin.stx
Errors fixed
P21) Error Message When Other Processes Accesses The MS SQL Server
Error
The following error message could appear: "Difference of two date time columns caused overflow at runtime" when the dates had a too wide span.