n RWF can be inserted in 1 ~ 13 board position of OptiX BWS 320G subrack.
n The optical connector on RWF board handle bar is of SC type.
4. Common alarm performance
RWF board mainly consists of optical receiving module and optical transmitting module, so its alarms mainly reflect the working status of these two modules. Alarms of RWF board are shown in Table 3-2.
Table 3-2 RWF board alarm table
Alarm description |
Alarm name |
Major cause of the alarm |
Status of alarm indicator |
Default alarm level |
Loss of signal at receiving side |
R-LOS |
No light input |
Flash 3 times continuously every other second |
Critical |
Out-of-frame at receiving side |
R-OOF |
Input optical power too low or excessive error codes during transmission |
Flash 3 times continuously every other second |
Critical |
Loss of frame at receiving side |
R-LOF |
Input optical power too low or excessive error codes during transmission |
Flash 3 times continuously every other second |
Critical |
Laser transmitting failure |
TF |
Fault occurs to laser of this board |
Flash 3 times continuously every other second |
Critical |
Laser service life will soon end |
LSR-WILL-DIE |
Laser damaged |
Flash 3 times continuously every other second |
Critical |
Laser cooling current cross threshold |
LSR-COOL-ALM |
Laser damaged or ambient temperature too high |
Flash twice continuously every other second |
Major |
Input power too low |
IN-PWR-LOW |
Input optical power too low |
Flash 3 times continuously every other second |
Critical |
Input power too high |
IN-PWR-HIGH |
Input optical power too high |
Flash 3 times continuously every other second |
Critical |
Transmitter deterioration |
TD |
Performance of laser deteriorates |
Flash 3 times continuously every other second |
Critical |
Output power too high |
OUT-PWR-HIGH |
Optical transmitting module fault or board parameter setting improper |
Flash twice continuously every other second |
Major |
Output power too low |
OUT-PWR-LOW |
Optical transmitting module fault or board parameter setting improper |
Flash twice continuously every other second |
Major |
Alarm of board not in position |
BDSTATUS |
No board in subrack slot, board mailbox fault or board not inserted properly |
Flash twice continuously every other second |
Major |
Regeneration section (B1) signal deterioration |
B1SD |
Input optical power too low or excessive error codes during transmission |
Flash once every other second |
Minor |
Regeneration section (B1) excessive error codes |
B1EXC |
Received signal attenuation too large |
Flash once every other second |
Minor |
3.1.3 STM-16 Transmitting Optical Wavelength Conversion Unit
1. Principle
The role of TWC board in OptiX BWS 320G system is to convert the optical wavelengths at the transmitting end and make the OptiX BWS 320G system become an open DWDM system. Its major function is to convert the STM-16 optical signals in the wavelength range of 1280~1565nm and in compliance with ITU-T G.957 recommendation into STM-16 optical signals with standard wavelengths recommended in ITU-T G.692, so that the signals can be multiplexed into one optical fiber.