n DWDM port receiver overload optical power: -9dBm (APD receiver module) or 0 dBm (PIN receiver module);
n Minimum receiving sensitivity of SDH side optical receiver: -21dBm.
n Overload optical power of SDH side optical receiver: 0dBm;
n It has regenerating function with performance indexes completely in compliance with ITU-T, such as input jitter tolerance, and jitter transfer characteristics, etc.;
n It provides regenerator section B1,J0 check and enables line fault location;
n LWC board provides the following monitoring functions: laser bias current monitoring, laser cooling current monitoring, laser transmitting optical power monitoring, and receiving optical power monitoring;
3. Applications
LWC combines the function of RWC and TWC together, and is added with the function of FEC(Forward Error Correction).
LWC can be inserted in 1~13 board position of OptiX BWS 320G subrack.
The optical connector on LWC board handle bar is of SC type.
4. Common alarm performance
LWC board is mainly composed of the optical transmitting module and optical receiving module, so its alarms mainly reflect the working status of these two modules. Alarms of LWC board are shown in Table 3-7.
Table 3-7 List of LWC board alarms
Alarm description |
Alarm name |
Major cause of the alarm |
Status of alarm indicator |
Default alarm level |
Loss of signal at receiving side |
R-LOS |
No light input |
Continuously flash for 3 times every other second |
Critical |
Out-of-frame at receiving side |
R-OOF |
Input optical power too low or excessive error codes during transmission |
Continuously flash for 3 times every other second |
Critical |
Loss of frame at receiving side |
R-LOF |
Input optical power too low or excessive error codes during transmission |
Continuously flash for 3 times every other second |
Critical |
Laser transmitting failure |
TF |
Laser fault of this board |
Continuously flash for 3 times every other second |
Critical |
Laser service life will soon end |
LSR-WILL-DIE |
Laser damaged |
Continuously flash for 3 times every other second |
Critical |
Laser cooling current cross threshold |
LSR-COOL-ALM |
Laser damaged or ambient temperature too high |
Continuously flash for twice every other second |
Major |
Input power too low |
IN-PWR-LOW |
Input optical power too low |
Continuously flash 3 times every other second |
Critical |
Input power too high |
IN-PWR-HIGH |
Input optical power too high |
Continuously flash 3 times every other second |
Critical |
Transmitter deterioration |
TD |
Performance of laser deteriorates |
Continuously flash 3 times every other second |
Critical |
Output power too high |
OUT-PWR-HIGH |
Optical transmitting module fault or board parameter setting improper |
Continuously flash twice every other second |
Major |
Output power too low |
OUT-PWR-LOW |
Optical transmitting module fault or board parameter setting improper |
Continuously flash twice every other second |
Major |
Alarm of board not in position |
BDSTATUS |
No board in subrack slot, board mailbox fault or board not inserted properly |
Continuously flash twice every other second |
Major |
Regeneration section (B1) signal deterioration |
B1SD |
Input optical power too low or excessive error codes during transmission |
Flash once every other second |
Minor |
Regeneration section (B1) excessive error codes |
B1EXC |
Received signal attenuation too large |
Flash once every other second |
Minor |