One SDH optical interface board provides different optical transmitting module for different transmission distance. The board should be selected based on the distance and attenuation between nodes during networking. Thus, avoid the receiver optical power below the receiver sensitivity or overload.
In a long-haul transmission, configure the optical amplifier boards such as JBA2, JBPA and JDCU based on the transmission distance.
2.3.3 BA/DCU
Table 2-7 lists the BA/DCU and their corresponding slots.
Table 2-7 Slots of BA and DCU
Board |
Slot |
JBA2 |
All IU slots and slots DCU, STI, EOW and SIG |
JBPA |
All IU slots and slots DCU, STI, EOW and SIG |
JDCU |
All IU slots and slots DCU, STI, EOW and SIG |
Normally, JBA2, JBPA and dispersion compensation unit (DCU) are used together with the long-haul optical transmitting module to support long distance transmission without regeneration. Here are the configuration requirements of the optical amplifier board:
n The optical transmitting module with L-64.2b optical interface should work with JBA2.
n The optical transmitting module with V-64.2b optical interface should work with JBA2, JBPA and JDCU.
n The optical transmitting module with U-16.2b optical interface should work with JBA2 and JBPA.
2.3.4 Ethernet Board
Table 2-8 shows the Ethernet board and the corresponding slots.
Table 2-8 Ethernet board and slots
Board |
Slot |
Remark |
GE06 |
IU01–IU40 |
Leading out from the front panel |
2.4 Network-Level Protection Configuration Requirement
2.4.1 Protection Modes for Networking
Table 2-9 shows the protection modes for conventional transmission network.
Table 2-9 Protection modes for conventional transmission network
Networking topology |
Protection mode |
Ring network |
SNCP, MSP |
Chain network |
1+1 or 1:1 linear MS protection |
Table 2-10 lists the protection modes for intelligent transmission network.
Table 2-10 Protection modes for intelligent transmission network
SLA service level |
Networking topology |
Protection mode |
Diamond |
Ring or chain network |
SNCP, 1+1 linear MS protection |
Gold |
Ring or chain network |
MSP, 1:1 linear MS protection |
Silver |
Mesh |
Re-routing protection |
Bronze |
Any network |
No protection when fault occurs. |
Iron |
Any network |
This kind of service (such as extra service) will be preempted by services at higher priority when the network resource is insufficient. |
Caution:
The OptiX OSN 9500 has no paired slot restriction. That is, any two optical interfaces of an SDH board can form a ring network. However, it is not recommended to form a ring using the optical interfaces at one board.
2.4.2 Configuration Requirement of SNCP
Table 2-11 shows the configuration requirements of SNCP.
Table 2-11 Configuration requirements of SNCP
No. |
Item |
Requirements |
1 |
DNI networking |
For SNCP, the master/slave nodes must be set correctly along the primary ring. |
2 |
Protection service capacity |
Maximum: 2304 SNCP services |
3 |
Co-existing with MSP |
To avoid mutual effect, set the SNCP delay time longer than 50 ms, which is the switching time of MSP. |
2.4.3 Configuration Requirement of MSP Ring
Table 2-12 shows the configuration requirements of MSP ring.
Table 2-12 Configuration requirements of MSP ring