Contents
2 Network Configuration Requirement 2-1
2.1 Network ID and IP Configuration Requirement 2-1
2.2 Intelligent Application Configuration Requirement 2-2
2.3 Board Configuration Requirement 2-3
2.3.1 Cross-Connect Board 2-3
2.3.2 SDH Board 2-3
2.3.3 BA/DCU 2-8
2.3.4 Ethernet Board 2-8
2.4 Network-Level Protection Configuration Requirement 2-8
2.4.1 Protection Modes for Networking 2-8
2.4.2 Configuration Requirement of SNCP 2-9
2.4.3 Configuration Requirement of MSP Ring 2-10
2.4.4 Configuration Requirement of Linear MSP 2-10
2.4.5 Re-route Protection Configuration Requirement 2-11
2.5 Equipment-Level Protection Configuration Requirement 2-11
2.6 Orderwire & ECC Configuration Requirement 2-12
2.6.1 Orderwire Configuration Requirement 2-12
2.6.2 ECC Configuration Requirement 2-13
2.7 Clock Configuration Requirement 2-14
2.7.1 Clock Configuration with SSM Not Enabled 2-15
2.7.2 Clock Configuration with SSM Enabled 2-16
2.7.3 Examples of Clock Configuration 2-17
2.8 Auxiliary Interface Configuration Requirement 2-19
Figures
Figure 2-1 Access capacity of slots in standard subrack with GXCH 2-4
Figure 2-2 Access capacity of slots in enhanced subrack with EXCH 2-5
Figure 2-3 Slot configuration requirements of equipment-level protection 2-12
Figure 2-4 Orderwire configuration 2-13
Figure 2-5 Networking of clock with SSM not enabled 2-15
Figure 2-6 Clock mutual tracing caused by fiber break 2-16
Figure 2-7 SSM application 2-16
Figure 2-8 Clock ring occurs when enabling SSM 2-17
Figure 2-9 Application of clock source ID 2-17
Figure 2-10 Clock configuration in chain network 2-18
Figure 2-11 Clock configuration in intersecting ring network 2-18
Figure 2-12 Clock configuration in tangent ring network 2-19
Figure 2-13 Auxiliary interface configuration 2-20
Tables
Table 2-1 Network ID and IP configuration requirements 2-2
Table 2-2 Intelligent application configuration requirements 2-2
Table 2-3 Configuration requirements of cross-connect board 2-3
Table 2-4 Correspondence between 20 G slots and 5 G slots 2-4
Table 2-5 SDH boards and slots 2-5
Table 2-6 Type and parameter of optical modules provided by SDH boards 2-6
Table 2-7 Slots of BA and DCU 2-8
Table 2-8 Ethernet board and slots 2-8
Table 2-9 Protection modes for conventional transmission network 2-9
Table 2-10 Protection modes for intelligent transmission network 2-9
Table 2-11 Configuration requirements of SNCP 2-9
Table 2-12 Configuration requirements of MSP ring 2-10
Table 2-13 Configuration requirements of linear MSP 2-10
Table 2-14 Re-route protection configuration requirements 2-11
Table 2-15 Configuration requirements of equipment-level protection 2-11
Table 2-16 Configuration requirements of network orderwire 2-12
Table 2-17 Configuration requirements of ECC 2-13
Table 2-18 Clock configuration requirements 2-14
Table 2-19 Clock priority table 2-15
Table 2-20 Functions of serial ports S1–S4 2-19
This chapter introduces the requirements on network configuration of the OptiX OSN 9500.
This chapter covers the contents as follows:
n Network ID and IP configuration requirement