Main Indices of the OptiX OSN 950. Permitted Frequency Deviation of Optical Input Interface. Output Frequency Precision of Internal Oscillator in Free-Run Mode, страница 7

Optical interface level

Optical interface type

Parameter requirement (dBm)

Test result

STM-1

S-1.1

< –28

Passed

STM-4

S-4.1

< –28

Passed

STM-16

I-16

< –18

Passed

S-16.1

< –18

Passed

L-16.1

< –27

Passed

L-16.2

< –28

Passed

Le-16.2

< –28

Passed

V-16.2

< –28

Passed

U-16.2

< –34

Passed

STM-64

I-64.1

< –11

Passed

S-64.2b

< –14

Passed

Le-64.2

<–22.5

Passed

L-64.2b

< –14

Passed

V-64.2b

< –23

Passed

100G EA

< –28

Passed

C.1.5  Receiver Overload (STM-16/4/1: BER=1 ´ 10-10; STM-64: BER=1 ´ 10-12)

Receiver overload is the maximum acceptable value of the received average power at point R for a specified BER. The receiver overload indices for the optical interface types provided by the OptiX OSN 9500 are in line with relevant requirements, as shown in Table C-10.

Table C-10 Receiver overload

Optical interface level

Optical interface type

Parameter requirement (dBm)

Test result

STM-1

S-1.1

> –8

Passed

STM-4

S-4.1

> –8

Passed

STM-16

I-16

> –3

Passed

S-16.1

> 0

Passed

L-16.1

> –9

Passed

L-16.2

> –9

Passed

Le-16.2

> –9

Passed

V-16.2

> –9

Passed

U-16.2

> –18

Passed

STM-64

I-64.1

> –1

Passed

STM-64

Le-64.2

> –9

Passed

S-64.2b

> –1

Passed

L-64.2b

> –3

Passed

V-64.2b

> –7

Passed

100G EA

> –1

Passed

C.1.6  Permitted Frequency Deviation of Optical Input Interface

In the free-run mode, the long-term frequency stability of the regenerator internal oscillator should not be less than ±20 x 10-6. And the input interface of the downstream SDH equipment can operate normally with such signals. The indices of the permitted frequency deviations of various optical input interfaces provided by the OptiX OSN 9500 are in line with relevant requirements, as shown in Table C-11

Table C-11 Permitted frequency deviation of optical input interfaces

Optical interface level

Parameter requirement (ppm)

Test result

STM-1

± 20

Passed

STM-4

± 20

Passed

STM-16

± 20

Passed

STM-64

± 20

Passed

C.1.7  AIS Rate Tolerance of Optical Output Interface

In the case of signal loss at the input interface of the SDH equipment, AIS should be output to the downstream via the output interface. The indices of the AIS rate tolerance of optical output interfaces for the various optical interfaces types provided by the OptiX OSN 9500 are in line with relevant requirements, as shown in Table C-12.