Note Provide V-16.2Je with BA, provide U-16.2Je with BA and PA, provide L-64.2b with BA, and provide V-64.2b with BA, PA and DCU.

One SDH optical interface board provides different optical transmitting modules for different transmission distances. The board should be selected according to the distance and attenuation between nodes during networking, to avoid the receiver optical power below the receiver sensitivity or overload.

In a long-haul transmission, configure the optical amplifier boards such as BA2, BPA and DCU based on the transmission distance.

3.  Paired Slot Requirement

When using the SDH board to configure the MSP ring, the two boards composing one ring should be inserted into the paired slots, as shown in Table A-5.

Table A-5 Paired slot

Paired slot

Slot 8

Slot 11

Slot 7

Slot 12

Slot 6

Slot 13

Slot 5

Slot 14

Slot 4

Slot 15

Slot 3

Slot 16

Slot 2

Slot 17

If it is the multiplex section shared optical path protection, then the two boards composing a ring need not to be inserted into the paired slots.

Refer to section A.4.5 “Configuration Requirements of Shared Optical Path MSP” for the configuration of multiplex section shared optical path protection.

A.2.3  Optical Amplifier Board

Table A-6 shows the optical amplifier boards and the corresponding slots.

Table A-6 Slots for optical amplifier boards and DCU

Board type

Slot

BA2

Slots 1–8, slots 11–17

BPA

Slots 1–8, slots 11–17

DCU

Slots 1–8, slots 11–17

Case optical amplifier 61COA/62COA

Installed in ETSI cabinet

Generally, the optical amplifier boards (BA2, BPA) and dispersion compensation unit (DCU) are used together with the long-haul optical transmitting module to support long distance transmission without regeneration. Here are the configuration requirements of the optical amplifier board:

n  Configure BA2 for the optical transmitting module with the optical interface type being V-16.2Je.

n  Configure BA2 and BPA for the optical transmitting module with the optical interface type being U-16.2Je.

n  Configure BA, PA and DCU for the optical transmitting module with the optical interface type being V-64.2b. If the transmission distance ranges from 70 km to 105 km, select the DCU of 60 km; if the distance ranges from 105 km to 120 km, select the DCU of 80 km.

COA helps the OptiX OSN 3500 to realize signal transmission from 80 km to 200 km.

A.2.4  PDH Board

Table A-7 lists the PDH boards, the corresponding interface boards and relevant slots.

Table A-7 PDH boards, interface boards and relevant slots

Board type

Slot

Interface board

Slot for interface board

SEP1

Slots 1–6, slots 13–16

It has no interface board. Lead out the trunk cable from the front panel

NA

SEP

Slots 2–5, slots 13–16

EU08, OU08, EU04 (Note)

Slot 19, slot 21, slot 23, slot 25, slot 29, slot 31, slot 33, slot 35

SPQ4

Slots 2–5, 13–16

MU04

Slot 19, slot 21, slot 23, slot 25, slot 29, slot 31, slot 33, slot 35

PD3

Slots 2–5, 13–16

D34S

Slot 19, slot 21, slot 23, slot 25, slot 29, slot 31, slot 33, slot 35

PL3

Slots 2–5, 13–16

C34S

Slot 19, slot 21, slot 23, slot 25, slot 29, slot 31, slot 33, slot 35

PQ1

Slots 1–5, 13–16

D75S, D12S, D12B

Slots 19–26, slots 29–36

PQM

Slots 1–5, 13–16

D75S, D12B

Slots 19–26, slots 29–36