Alarm Lists. Regenerator section (B1) excessive errors. The board alarm indicator flashes once every other second. Regenerator section (B1) signal degraded, страница 7


OUT-PWR-LOW

Item

Description

Alarm Name

OUT-PWR-LOW

Name

Output power is too low

Alarm Level

Major

Alarm Category

Equipment alarm

Alarm Board

TWF/TWC/RWF/RWC/ LWC/OCU/WPA/WBA/WLA

Alarm Indication

The alarm indicator of the board flashes twice every other second

Alarm Reasons

(1) EDFA module fault.

(2) The input optical power is abnormal.

Processing Methods

(1) Measure the input optical power to observe whether the optical power is decreased obviously.

(2) Reset or unplug/plug the board.

(3) Replace the faulty board.

Remarks


PUM-BCM-ALM

Item

Description

Alarm Name

PUM-BCM-ALM

Name

Working current of pump laser over threshold

Alarm Level

Major

Alarm Category

Equipment alarm

Alarm Board

WPA/WBA/WLA

Alarm Indication

The alarm indicator of the board flashes twice every other second

Alarm Reasons

(1) EDFA module fault.

Processing Methods

(1) Reset and unplug/plug the board.

(2) Replace the faulty board.

Remarks


PUM-COOL-ALM

Item

Description

Alarm Name

PUM-COOL-ALM

Name

Cool current of pump laser over threshold

Alarm Level

Critical

Alarm Category

Equipment alarm

Alarm Board

WPA/WBA/WLA

Alarm Indication

The alarm indicator of board flashes three times every other second

Alarm Reasons

(1) EDFA module fault.

Processing Methods

(1) Reset or unplug/plug the board.

(2) Replace the faulty board.

Remarks


PUM-TEM-ALM

Item

Description

Alarm Name

PUM-TEM-ALM

Name

Working temperature of the pump laser over threshold

Alarm Level

Major

Alarm Category

Equipment alarm

Alarm Board

WPA/WBA/WLA

Alarm Indication

The alarm indicator of the board flashes twice every other second

Alarm Reasons

(1) EDFA module fault.

Processing Methods

(1) Reset, unplug/plug the board.

(2) Replace the faulty board.

Remarks


RELAY-ALARM

Item

Description

Alarm Name

RELAY-ALARM

Name

Relay alarm

Alarm Level

Critical

Alarm Category

Environment alarm

Alarm Board

PMU

Alarm Indication

The alarm indicator of the board flashes three times every other second

Alarm Reasons

(1) The relay state is changed.

Processing Methods

(1) Check whether the alarm status is changed.

Remarks


R-LOF