Alarm Lists. Regenerator section (B1) excessive errors. The board alarm indicator flashes once every other second. Regenerator section (B1) signal degraded, страница 3

Item

Description

Alarm Name

CRC4-CROSSTR

Name

CRC4 multi-frame error code count over threshold

Alarm Level

Minor

Alarm Category

Service quality alarm

Alarm Board

SC1/SC2

Alarm Indication

The board alarm indicator flashes once every other second

Alarm Reasons

(1) Excessive optical path attenuation causes that input optical power is too low.

(2) The received optical signal is overloaded.

Processing Methods

(1) Measure the receiving optical power. If it is normal, replace the board.

(2) If the service is not affected, check whether the fiber pigtail from SCA board to SC2/SC1 is squeezed.

Remarks


DBMS-ERROR

Item

Description

Alarm Name

DBMS-ERROR

Name

Data base error

Alarm Level

Major

Alarm Category

Process alarm

Alarm Board

SCC

Alarm Indication

The alarm indicator of the board flashes twice every other second

Alarm Reasons

(1) The database operation fails.

(2) The database data is damaged.

(3) Board fault.

Processing Methods

(1) Reset, unplug/plug the board.

(2) Replace the faulty board.

Remarks

When replacing SCC board, the host software and the sent configuration should be matched.


EPROM-ERR

Item

Description

Alarm Name

EPROM-ERR

Name

EPROM reading or writing error

Alarm Level

Critical

Alarm Category

Equipment alarm

Alarm Category

MS2

Alarm Indication

The alarm indicator of board flashes three times every other second

Alarm Reasons

(1) Board fault.

Processing Methods

(1) Reset, unplug/plug the board.

(2) Replace the faulty board.

Remarks


FAN -FAIL

Item

Description

Alarm Name

FAN-FAIL

Name

Fan failed

Alarm Level

Major

Alarm Category

Equipment alarm

Alarm Board

SCC

Alarm Indication

The alarm indicator of the board flashes twice every other second

Alarm Reasons

(1) Fan is off.

(2) Fan failure.

Processing Methods

(1) Check whether fan is turned on.

(2) Check whether fan is in normal operation.

(3) Replace the faulty fan.

Remarks


IN-PWR-HIGH

Item

Description

Alarm Name

IN-PWR-HIGH

Name

Input power is too high

Alarm Level

Critical

Alarm Category

Equipment alarm

Alarm Board

WPA/WBA/WLA

Alarm Indication

The alarm indicator of the board flashes three times every one second

Alarm Reasons

(1) The input optical power is too high.

Processing Methods

(1) Check whether the receiving optical power of home station is too high; if not, replace the board.

(2) If the optical power increases abruptly, the attenuation of the front end variable attenuator at the front end of the optical amplifier board might be reduced or broken down. Readjust attenuation value or replace the attenuator and adjust the optical power to normal value.

Remarks