Alarm Lists. Regenerator section (B1) excessive errors. The board alarm indicator flashes once every other second. Regenerator section (B1) signal degraded, страница 4


IN-PWR-LOW

Item

Description

Alarm Name

IN-PWR-LOW

Name

Input power is too low

Alarm Level

Critical

Alarm Category

Equipment alarm

Alarm Board

WPA/WLA/WBA

Alarm Indication

The alarm indicator of the board flashes three times every other second

Alarm Reasons

(1) The input optical power is too low.

Processing Methods

(1) Measure the input optical power; if the optical power is normal, replace the board.

(2) If the input optical power is decreased, check whether attenuation of the front end variable attenuator in the optical amplifier board is increased.

(3) Check the transmitting optical power of opposite station. If normal, check whether abnormal attenuation occurs in the optical path.

Remarks


IN-SIG-LOSS

Item

Description

Alarm Name

IN-SIG-LOSS

Name

Loss of input signal

Alarm Level

Critical

Alarm Category

Equipment alarm

Alarm Board

WPA/WBA/WLA

Alarm Indication

The alarm indicator of board flashes three times every other second

Alarm Reasons

(1) There is no input optical signal.

(2) EDFA module fault.

Processing Methods

(1) Measure the input optical power; if normal, replace the optical amplifier board.

(2) First check whether the variable attenuator of the front optical amplifier board is damaged.

(3) Check whether the transmitting optical power of opposite station is normal; if yes, check whether abnormal attenuation occurs in the optical path.

Remarks

LSR-BCM-ALM

Item

Description

Alarm Name

LSR-BCM-ALM

Name

Set bias current of the laser over threshold

Alarm Level

Major

Alarm Category

Equipment alarm

Alarm Board

WPA/WBA/WLA

Alarm Indication

The alarm indicator of the board flashes twice every other second

Alarm Reasons

(1) The laser is aged.

(2) Board fault..

Processing Methods

(1) Reset, unplug/plug the board.

(2) Replace the faulty board.

Remarks


LSR-COOL-ALM

Item

Description

Alarm Name

LSR-COOL-ALM

Name

Cooling current of the laser over threshold

Alarm Level

Major

Alarm Category

Equipment alarm

Alarm Board

TWF/TWC/RWF/RWC/LWC/OCU/SC1/SC2/WPA/WBA/WLA

Alarm Indication

The alarm indicator of the board flashes twice every other second

Alarm Reasons

(1) Cooling loop fault.

(2) The ambient temperature over threshold

Processing Methods

(1) Check whether the ambient temperature of the equipment room is normal.

(2) If the temperature of the equipment room is normal, replace the board to solve the problem.

Remarks


LSR-DRI-ALM