Table 9 |
|||||||
(1) Shims for the Pressure Control Valve Pressure Change per Shim |
|||||||
Station (1) |
A |
B |
C |
D (2) |
E |
F |
G |
Engaged Clutch |
2 |
1 |
3 |
- |
4 |
5 |
6 |
Thickness of Shim |
Pressure Change |
Pressure Change |
Pressure Change |
Pressure Change |
Pressure Change |
Pressure Change |
Pressure Change |
5J-2721 Shim |
|||||||
0.13 mm (0.005 inch) |
20 kPa (2.9 psi) |
17 kPa (2.5 psi) |
20 kPa (2.9 psi) |
12 kPa (1.7 psi) |
17 kPa (2.5 psi) |
14 kPa (2.0 psi) |
19.5 kPa (2.83 psi) |
6J-3993 Shim |
|||||||
0.25 mm (0.010 inch) |
41 kPa (5.9 psi) |
33 kPa (4.8 psi) |
41 kPa (5.9 psi) |
25 kPa (3.6 psi) |
35 kPa (5.1 psi) |
28 kPa (4.1 psi) |
38.5 kPa (5.58 psi) |
4M-1751 Spacer |
|||||||
0.41 mm (0.016 inch) |
65 kPa (9.4 psi) |
53 kPa (7.7 psi) |
65 kPa (9.4 psi) |
39 kPa (5.7 psi) |
56 kPa (8.1 psi) |
45 kPa (6.5 psi) |
62 kPa (9.0 psi) |
5J-1036 Shim |
|||||||
0.80 mm (0.031 inch) |
125 kPa (18.2 psi) |
103 kPa (14.9 psi) |
125 kPa (18.2 psi) |
76 kPa (11.0 psi) |
109 kPa (15.8 psi) |
87 kPa (12.6 psi) |
120 kPa (17.4 psi) |
( 1 ) |
Station "H" is not used. |
( 2 ) |
Station "D" does not control a clutch. Station "D" controls the dual stage relief valve for the system pressure. |