Руководство к решению задач по строительной механике в 3 частях. Часть 2: Учебное пособие, страница 17

Продолжение табл. 10.1

Схема 6

Нижний пояс

Верхний пояс

Стойки

Раскосы

N1–3 = –20,00 кН

N2–4 = 20,00 кН

N1–4 = 60,00 кН

N1–2 = –36,06 кН

N3–5 = –100,00 кН

N4–6 = 100,00 кН

N3–6 = –170,00 кН

N3–4 = –144,22 кН

N5–7 = –26,67 кН

N6–8 = 26,67 кН

N5–8 = –110,00 кН

N5–6 = 132,20 кН

N7–9 = 0 кН

N8–10 = –6,67 кН

N7–10 = –60,00 кН

N7–8 = 60,09 кН

N9–11 = –80,00 кН

N10–12 = –6,67 кН

N9–12 = –70,00 кН

N7–12 = 12,0 кН

N11–13 = –20,00 кН

N12–14 = 0 кН

N11–14 = –180,0 кН

N9–14 = 144,2кН

N14–15 = 80,00 кН

N13–15 = 30,00 кН

N11–15 =–108,2 кН

N15–16 = 20,00 кН

N13–16 =–36,1кН

Схема 7

Нижний пояс

Верхний пояс

Стойки

Раскосы

N1–3 = 0 кН

N2–4 = –100,38 кН

N1–2 = –134,67 кН

N2–3 = 200,75 кН

N3–5 = 89,78 кН

N4–6 = –247,45 кН

N3–4 = –131,56 кН

N4–5 = 237,16 кН

N5–7 = 221,33 кН

N6–8 = –238,00 кН

N5–6 = –149,33 кН

N6–7 = 23,57 кН

N7–9 = 206,67 кН

N8–10 = –238,00 кН

N7–8 = 0 кН

N7–10 = 44,31 кН

N9–11 = 84,89 кН

N10–12 = –231,09 кН

N9–10 = –134,67 кН

N9–12 = 219,54 кН

N11–13 = 0 кН

N12–14 = –94,91 кН

N11–12 = –121,8 кН

N11–14 = 189,8 кН

N13–14 = –161,3кН

Схема 8

Нижний пояс

Верхний пояс

Стойки

Раскосы

N1–3 = 401,00 кН

N2–4 = 0 кН

N1–2 = –72,00 кН

N1–4 = –802,00 кН

N3–5 = 1042,0 кН

N4–6 = –358,67 кН

N3–4 = 573,33 кН

N3–6 = –1033,6 кН

N5–7 = 932,00 кН

N6–8 = –1140,0 кН

N5–6 = 508,00 кН

N6–7 = 294,16 кН

Схема 8

Нижний пояс

Верхний пояс

Стойки

Раскосы

N7–9 = 1140,0 кН

N8–10 = –1204,0 кН

N7–8 = –208,00 кН

N8–9 = 90,51 кН

N9–11 = 1124,0 кН

N10–12 = –1204,0 кН

N9–10 = –144,00 кН

N9–12 = 113,14 кН

N11–13 = 900,00 кН

N12–14 = –1124,0 кН

N11–12 = –224,00 кН

N11–14 = 316,8 кН

N13–15 = 1006,2 кН

N14–16 = –354,67 кН

N13–14 = 450,00 кН

N14–15 = –983,1кН

N15–17 = 396,53 кН

N16–18 = 0 кН

N15–16 = 565,33 кН

N16–17 = –793,1 кН

N17–18 = –72,00 кН

Схема 9

Нижний пояс

Верхний пояс

Стойки

Раскосы

N1–3 = 0 кН

N2–4 = 25,92 кН

N1–2 = 40,00 кН

N2–3 = –34,71 кН

N3–5 = 75,28 кН

N4–6 = 25,92 кН

N3–4 = 0 кН

N3–6 = –253,50 кН

N5–7 = 122,22 кН

N6–8 = –75,28 кН

N5–6 = 192,67 кН

N5–8 = –122,06 кН

N7–9 = 135,83 кН

N8–10 = –122,22 кН

N7–8 = 112,67 кН

N7–10 = –35,39 кН

N9–11 = 135,83 кН

N10–12 = –116,11 кН

N9–10 = 80,00 кН

N10–11 = –51,28 кН

N11–13 = 116,11 кН

N12–14 = –63,06 кН

N11–12 = 127,33 кН

N12–13 = –137,9 кН

N13–15 = 63,06 кН

N14–16 = 36,28 кН

N13–14 = 207,33 кН

N14–15 = –244,8 кН

N15–17 = 0 кН

N16–18 = 36,28 кН

N15–16 = 0 кН

N15–18 = –48,60 кН

N17–18 = 40,00 кН

Продолжение табл. 10.1