Each node is required to provide Ethernet services.

The trunk line adopts the 10 Gbit/s bandwidth for the future increase of traffic. All services need network-level protection. Figure 3-1 shows the position of each node and the optical cable distribution status.

Figure 3-1 Geographic position of each node and optical cable distribution status

Here lists the basic information of the project:

n  There is 10 Gbit/s backbone network between central node A and city 1.

n  Nodes A, B, C, D and E connect to each other with two-core or four-core fibers.

n  Nodes A, B, C and D are responsible for the service convergence and grooming, the fiber among them are 10 Gbit/s. The fiber between D and E is 2.5 Gbit/s.

n  A-1, A-2, B-1, D-1, D-2, E-1 and E-2 are newly constructed access nodes.

n  Nodes A, A-1 and A-2 can form a ring network of 155 Mbit/s or 622 Mbit/s according to the new route status and traffic requirement. In addition, each of the following groups can form the low-rate ring network: nodes B, B-1 and C, nodes D, D-1 and D-2, nodes E, E-1 and E-2.

n  The network management system is in central node A.


3.1.2  Service Requirement

1.  SDH Service

Table 3-2 SDH service requirement of each node

Service requirement

Node

SDH service (line)

SDH service (tributary)

A

3 x STM-64

2 x STM-16

16 x STM-1(E)

16 x STM-1(O)

B

4 x STM-64

8 x STM-4

16 x STM-1(O)

C

4 x STM-64

16 x STM-1(E)

8 x STM-4

D

2 x STM-64

4 x STM-16

16 x STM-1(E)

E

2 x STM-16

2 x STM-16

16 x STM-1(E)

A-1

2 x STM-16

A-2

2 x STM-16

B-1

2 x STM-64

D-1

2 x STM-16

D-2

2 x STM-16

E-1

2 x STM-16

E-2

2 x STM-16

2.  Ethernet Service

Table 3-3 Ethernet service requirement of each node

No.

Service requirement

Source station

Sink station

Bandwidth

(1)

Point-to-point

C

A

1000 Mbit/s

(2)

Point-to-point

B

A

1000 Mbit/s

(3)

Point-to-point

D

A

1000 Mbit/s

(4)

Point-to-point

A

City1

1000 Mbit/s

3.1.3  Protection Requirement

1.  Network-Level Protection Requirement

The ring and chain require network protection with switching time less than 50 ms when there is fiber-cut or optical board fault.

2.  Ethernet Service Protection Requirement

The protection can be implemented at the SDH layer or data service layer.

3.  Equipment-Level Protection Requirement

Table 3-4 Equipment-level protection requirement

Node

Clock board backup

Cross-connect board backup

SCC backup

Power supply unit backup

Working power backup

A

Ö

Ö

´

Ö

Ö

B

Ö

Ö

´

Ö

Ö

C

Ö

Ö

´

Ö

Ö

D

Ö

Ö

´

Ö

Ö

E

Ö

Ö

´

Ö

Ö

3.1.4  Network Clock Requirement