Each node is required to provide Ethernet services.
The trunk line adopts the 10 Gbit/s bandwidth for the future increase of traffic. All services need network-level protection. Figure 3-1 shows the position of each node and the optical cable distribution status.
Figure 3-1 Geographic position of each node and optical cable distribution status
Here lists the basic information of the project:
n There is 10 Gbit/s backbone network between central node A and city 1.
n Nodes A, B, C, D and E connect to each other with two-core or four-core fibers.
n Nodes A, B, C and D are responsible for the service convergence and grooming, the fiber among them are 10 Gbit/s. The fiber between D and E is 2.5 Gbit/s.
n A-1, A-2, B-1, D-1, D-2, E-1 and E-2 are newly constructed access nodes.
n Nodes A, A-1 and A-2 can form a ring network of 155 Mbit/s or 622 Mbit/s according to the new route status and traffic requirement. In addition, each of the following groups can form the low-rate ring network: nodes B, B-1 and C, nodes D, D-1 and D-2, nodes E, E-1 and E-2.
n The network management system is in central node A.
3.1.2 Service Requirement
1. SDH Service
Table 3-2 SDH service requirement of each node
Service requirement Node |
SDH service (line) |
SDH service (tributary) |
A |
3 x STM-64 |
2 x STM-16 16 x STM-1(E) 16 x STM-1(O) |
B |
4 x STM-64 |
8 x STM-4 16 x STM-1(O) |
C |
4 x STM-64 |
16 x STM-1(E) 8 x STM-4 |
D |
2 x STM-64 |
4 x STM-16 16 x STM-1(E) |
E |
2 x STM-16 |
2 x STM-16 16 x STM-1(E) |
A-1 |
2 x STM-16 |
|
A-2 |
2 x STM-16 |
|
B-1 |
2 x STM-64 |
|
D-1 |
2 x STM-16 |
|
D-2 |
2 x STM-16 |
|
E-1 |
2 x STM-16 |
|
E-2 |
2 x STM-16 |
2. Ethernet Service
Table 3-3 Ethernet service requirement of each node
No. |
Service requirement |
Source station |
Sink station |
Bandwidth |
(1) |
Point-to-point |
C |
A |
1000 Mbit/s |
(2) |
Point-to-point |
B |
A |
1000 Mbit/s |
(3) |
Point-to-point |
D |
A |
1000 Mbit/s |
(4) |
Point-to-point |
A |
City1 |
1000 Mbit/s |
3.1.3 Protection Requirement
1. Network-Level Protection Requirement
The ring and chain require network protection with switching time less than 50 ms when there is fiber-cut or optical board fault.
2. Ethernet Service Protection Requirement
The protection can be implemented at the SDH layer or data service layer.
3. Equipment-Level Protection Requirement
Table 3-4 Equipment-level protection requirement
Node |
Clock board backup |
Cross-connect board backup |
SCC backup |
Power supply unit backup |
Working power backup |
A |
Ö |
Ö |
´ |
Ö |
Ö |
B |
Ö |
Ö |
´ |
Ö |
Ö |
C |
Ö |
Ö |
´ |
Ö |
Ö |
D |
Ö |
Ö |
´ |
Ö |
Ö |
E |
Ö |
Ö |
´ |
Ö |
Ö |
3.1.4 Network Clock Requirement