Contents
A Indicator List A-1
A.1 Cabinet Indicators A-1
A.2 Board Indicators A-2
A.2.1 Alarm Indicators A-2
A.2.2 Running Indicators A-3
A.2.3 Ethernet Indicators A-3
A.2.4 Fan Tray Assembly Indicator A-4
A.2.5 JPIU Board Indicator A-4
A.2.6 JPBU Board Indicator A-4
Tables
Table A-1 Cabinet indicators A-1
Table A-2 Board alarm indicators A-2
Table A-3 Board running indicator A-3
Table A-4 Ethernet interface indicators A-4
Table A-5 JFAN board indicator description A-4
A.1 Cabinet Indicators
On top of the OptiX OSN 9500 cabinet, there are two rows of indicators, 3 indicators in the front and the other 3 indicators in the rear. The 3 indicators are respectively red, yellow, and green in color. Indicators in the front demonstrate the alarm status in the same manner as those in the rear, so that the alarm indicators can be watched both in front of the cabinet and from behind. When the indicator illuminates, it indicates that the alarm indication signal (AIS) is valid. When the indicator is off, it indicates that AIS is invalid. See Table A-1.
Table A-1 Cabinet indicators
Type |
Name |
Description |
Red indicator |
Critical indicator |
Critical alarm occurs. |
Yellow indicator |
Major alarm indicator |
Major alarm occurs. |
Orange indicator |
Minor alarm indicator |
Minor alarm occurs. |
Green indicator |
Power indictor |
Cabinet power is on. |
Note: when the indicator illuminates, it indicate that AIS is valid. When it is off, it indicates that AIS is invalid. |
A.2 Board Indicators
A.2.1 Alarm Indicators
Board alarm indicators are red.
1. Alarm Indicators on the Front Panel
Table A-2 shows various working statuses of board alarm indicators.
Table A-2 Board alarm indicators
Red indicator flashing description |
Meaning |
Parameters |
The red indicator is on, and the green one is off. |
Memory self-check error |
The red indicator is on. |
The red indicator flashes for 3 times, and pauses 1 second, then flashes for 3 times. |
Critical alarm |
The red indicator keeps on for 0.3 second, flashes for 3 times within 0.3 second, and keeps off for 1 second. |
The red indicator flashes twice, pauses 1 second, then flashes twice. |
Major alarm |
The red indicator keeps on for 0.3 second, and flashes twice within 0.3 second, and keeps off for 1 second. |
The red indicator flashes once, pauses 1 second, then flashes once |
Minor alarm |
The red indicator keeps on for 0.3 second, flashes once within 0.3 second, and keeps off for 1 second. |
The red indicator and the green indicator flash simultaneously at the frequency of twice every second. |
The lower layer software is running or software uploading is going on. |
Both the red indicator and the green indicator keep on or off for 0.3 second simultaneously |